订购/客服:021-61998551/13122364865

嗜酸性粒细胞过氧化物酶(EPX)重组蛋白(Mouse,小鼠)

Recombinant Eosinophil Peroxidase (EPX)
别名: EPO; EPP; EPX-PEN; EPER
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。 
嗜酸性粒细胞过氧化物酶(EPX)重组蛋白(Mouse,小鼠)
货号 规格 可用库存 销售价(RMB) 您的折扣价(RMB) 购买数量
ZY60791MuP-10μg 10μg 现货 840.00 840
  • ZY60853BP

    脂肪酸结合蛋白 4(FABP4)重组蛋白(Cattle,牛)
  • ZY63189HuP

    IgG-Fc片段低亲和力受体Ⅲb(FcgR3B)重组蛋白(Human,人)
  • ZY66414HuP

    谷胱甘肽过氧化酶4(GPX4)重组蛋白(Human,人)
  • ZY63822PP

    结合珠蛋白(Hpt)重组蛋白(Pig,猪)
  • ZY66986HuP

    SPARC相关组件钙结合蛋白1(SMOC1)重组蛋白(Human,人)
  • ZY65429MuP

    Ⅵ型胶原α1(COL6a1)重组蛋白 (Mouse,小鼠)
  • ZY66105HuP

    白介素1受体关联激酶2(IRAK2)重组蛋白 (Human,人)
  • ZY65323HuP

    氨基乙二酸半醛磷酸泛酰巯基乙胺基转移酶(AASDHPPT)重组蛋白(Human,人)
  • ZY61411HuP

    腺苷A2a受体(ADORA2a)重组蛋白(Human,人)
  • ZY64793RP

    含卷曲螺旋域蛋白60(CCDC60)重组蛋白(Rat,大鼠)
  • ZY62093HuP

    死亡诱导终结因子1(DIDO1)重组蛋白 (Human,人)
  • ZY63061RP

    岩藻糖基转移酶1(FUT1)重组蛋白 (Rat,大鼠)
熔点:
密度:
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。

 嗜酸性粒细胞过氧化物酶(EPX)重组蛋白

规格及价格:

规格 价格
10µg 840
50µg 2100
200µg 4200
1mg 12600
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Gln19~Arg300
Tags: N-terminal His and GST Tag
Subcellular Location: Cytoplasm
Purity: > 80% 
Traits: Freeze-dried powder
Buffer formulation: PBS, pH7.4, containing 0.01% SKL, 5% Trehalose .
Original Concentration: 400µg/mL
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 10.0
Predicted Molecular Mass: 61.8kDa
Accurate Molecular Mass: 62/28kDa as determined by SDS-PAGE reducing conditions.
[ USAGE ]
Reconstitute in 10mM PBS (pH7.4) to a concentration of 0.1-1.0 mg/mL. Do not vortex.
[ STORAGE AND STABILITY ]
Storage:Avoid repeated freeze/thaw cycles.
Store at 2-8ºC for one month.
Aliquot and store at -80ºC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determinedby accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and noobvious degradation and precipitation were observed. The loss rate is less than 5% within theexpiration date under appropriate storage condition.
[ SEQUENCE ]

[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit wasused in clinical diagnostic or any other procedures.
特别提示:本公司的所有产品仅可用于科研实验,严禁用于临床医疗及其他非科研用途!以实际收货产品说明书为准,网站说明书仅供参考。
  • 专业包装 正品保证

  • 快乐服务 售后无忧

  • 会员特权 优惠不断

  • 个人信息 严格保护


© 2005-2025 泽叶生物网站 版权所有,并保留所有权利。
沪ICP备16043273号-2号